OPTIONAL ACCESSORIES

Selection of practical, functional and aesthetic solutions according to the type of fireplace insert:

Type, material or colour of the firebox  –  Position of the firebox  –  Type of glazing  –  Design of the cover frame  –  Variation of the control elements  –  Addition of accumulation elements – Hot air and hot water exchanger –  Change of the ash tray  –  Integration of a second casing  –  Solution with folding door  – Designer grid frame –  Supporting structure  –  Adding a post at the glass junction.

SEGMENT CHAMOTTE LINNING /SO on the left and SOČ on the right/
  • SEGMENT CHAMOTTE LINNING /SO/
  • Division of the fireplace into smaller, fitting into each other chamotte segments.
  • The main advantages of the segmented design are the elimination of internal stress (the micro-gaps between the segments act as expansion joints) and simple, cost-effective servicing (a damaged segment can be replaced without replacing the entire firebox).
  • Increased thickness of the refractory fireclay provides greater durability and heat accumulation
  • Variants:
      • light segment chamotte lining – SO (brick design)
      • black segment chamotte lining – SOČ (brick design)
Lower Hearth /ZO/
  • LOWER HEARTH /ZO/
  • Designed for installation in low-positioned portal fireplaces
  • The advantage of this design is the pleasant radiant heat emitted from floor level
  • Enhances the visual effect of the flames within the space
  • Construction height from the bottom base: 200 mm
Reflex glass /SR/
  • REFLEX GLASS /SR/
      • Internal refractory ceramic glass
      • Glass with a reflective coating reduces the amount of radiant heat that enters a space
      • Greater thermal comfort – the area in front of the fireplace does not overheat
      • Suitable for modern low-energy buildings
      Black printed glass /SM/
      • BLACK PRINTED GLASS /SM/
      • Refractory ceramic glass – external
      • The black print design, combined with the moulding (in stainless steel or black)
      • Gives the fireplace insert a modern look
      • The glass appears visually larger, creating a frameless effect
      • Particularly suitable for fireplaces in modern interiors
      Control grip-handle
      • CONTROL GRIP-HANDLE
      • For controlling the door movement
      • Depending on the size and type of fireplace insert, as well as the type of door opening
      • Fixed or removable
      • Stainless steel (inox) or black 
      •  for:
        • LD design door  –  fixed grip-handle RP2
        • LD2 design door – lever RP1
        • VD design door:
            • removable grip-handle MO1, or
            • fixed grip-handle MP2 or MP3
      Cover Frames (from left to right) KR-VDA, KR-A, KRP-I
      • COVER FRAME /KR/
      • Enhances the aesthetic appearance and conceals the expansion seal around the fireplace insert
      • Available in steel or brushed stainless steel
      • Fixed / removable
      • KRO-VDA: removable cover frame for fireplace inserts with VD door opening, in VDA design, i.e. an “L”-profile frame with a standard 25 mm trim
      • KRO-A: for fireplace inserts with LD door opening, in A design, i.e. an “L”-profile frame with a standard 30 mm trim; available in 2S / 3S / 4S versions (2-/3-/4-sided)
      • KRP-I: fixed cover frame – 5 mm thick “I”-profile, zero trim
      Rear charging door /PD/
      • REAR CHARGING DOOR /PD/
      • Loading door
      • Double-sided designs of fireplace inserts
      • Door shield design (sheet metal/chamotte), helps prevent radiant heat from reaching the area
      • Allows fuel to be loaded from an adjacent room or from a different side of the fireplace, even while the appliance is in operation
      • Available either as a full door or as a loading door with a viewing window
      • The loading door can be fitted with a decorative cover frame
      HOT WATER EXCHANGER /TV/
      • HOT WATER EXCHANGER /TV/
      • The fireplace insert with an integrated water heat exchanger provides hot water for the central heating system
      • The water heat exchangers are designed for installation with the following fireplace inserts:  CHOPOK L LD, CHOPOK L VD, CHOPOK L LD PD, CHOPOK L VD PD  and with the following fireplace stoves ROTO a KPL
      • The connection of each appliance to the system must be designed by a qualified designer and carried out by an authorised professional
      HOT AIR EXCHANGER: VERTIKAL, NADSTAVBA
      • HOT AIR EXCHANGER
      • Efficiently utilises otherwise unused energy from flue gases
      • The hot air heat exchangers are designed for connection to ROTO and KPL fireplace stoves
      • 2 types: 1,5kW NADSTAVBA  and 3kW VERTIKAL
      APOS accessory applied to: CHOPOK L LD on the left, KAZETA O LD on the right
      • CHAMOTTE HEAT ACCUMULATION QUADRANT 170 190 210 260 /APOS/
      • The additional heat storage set consists of five rows of heat storage segments forming a cylindrical segmented unit
      • Installation: around the flue pipe
      • The stored heat is released into the room steadily and evenly, even after the fire has gone out
      • Material: chamotte
      • Available sizes: DN 170, DN 190, DN 210 and DN 260 (inner ring diameter)
      AV accessory aplied to : STABIL R90 on the left, CHOPOK ST R90 on the right
      • INTEGRATED ACCUMULATION HEAT EXCHANGER /AV/
        • The additional heat storage set consists of five rows of heat storage segments forming an oval segmented cylinder.
        • Installation: around the steel body of the fireplace insert
        • It stores the heat transferred from the steel body to the fireclay lining.
        • The stored heat is released into the room steadily and evenly, even after the fire has gone out.
        • It helps prevent overheating of the building.
        • The heat storage units are designed for EKO, CHOPOK and STABIL fireplace insert ranges in L, O, R90 and 2R90 configurations, as well as for ROTO and KPL fireplace stoves.
        VERTICAL HEAT-STORING PANEL  /AZ/
        • VERTICAL HEAT-STORING PANEL /AZ/
        • Additional accumulation anchored by suspension elements around of casing the fireplace
        • The number of hanging accumulators required depends on the shape and size of the fireplace insert (2 to 5 pieces)
        CONVECTIONAL CASING  /DP/
        • CONVECTIONAL CASING /DP/
        • The convective secondary casing facilitates the construction of the fireplace enclosure and the distribution of warm air.
        • Faster air circulation between the fireplace insert and the additional secondary casing enables the room to heat up more quickly.
        • The heating system operates more efficiently.
        • The secondary casing is essential when the fireplace is used to heat multiple rooms
        EXTERNAL ASHTRAY /VOP/
        • EXTERNAL ASHTRAY /VOP/
        • The ash pan is separated from the combustion chamber.
        • Separate access door – the ash pan can be operated independently of the main fireplace door.
        • Structurally integrated into the fireplace base.
        • The ash pan housing has an adjustable depth.
        • The removable ash container allows for easy and clean ash removal and handling.
        INTEGRAL BUILDING LINTEL /SPI/
        • INTEGRAL BUILDING LINTEL /SPI/
        • An additional load-bearing structure directly integrated into the fireplace insert construction
        • Increases the load-bearing capacity of the fireplace insert
        • Evenly distributes the weight of the heavy fireplace enclosure around the insert, eliminating point loads on the floor
          Stavebný preklad SP
          • CONSTRUCTION LINTEL /SP/
          • Additional structural component
          • Increases the load-bearing capacity of the fireplace insert
          • Evenly distributes the weight of the fireplace insert over a larger area
          CONSTRUCTION BASE /MS/
          • CONSTRUCTION BASE /MS/
          • Separate supporting base
          • Designed for the installation of the CA fireplace insert
          TRANSPORT MOUNTING LEGS
          • TRANSPORT MOUNTING LEGS
          • Auxiliary installation accessory designed for the easy and safe movement of the fireplace insert inside the building
          • The mounting leg is compatible with the fireplace insert’s existing leg structure
          • The mounting legs can be used with all KOBOK fireplace insert models
          DESIGN GRID – TUNEL
          • DESIGN GRID – TUNEL
          • Aesthetically complements the fireplace insert, creating a perfectly coordinated and unified appearance
          • The grids are supplied as a set (upper + lower)
          • Made from the same material as the trim frame
          • The grid placement is coordinated with the insert configuration (L, O, R90 – left/right, 2R90, O/R90) and the overall design of the fireplace insert
          • This product is not part of the standard range and is manufactured exclusively on request
          FIXED CORNER  / PILLAR AT THE GLASS JUNCTION (S)
          • FIXED CORNER / PILLAR AT THE GLASS JUNCTION
          • For corner fireplace inserts with an LD door opening
          • Classic fireplace insert design: fixed corner post(s) on the corner(s) of the fireplace insert, with the door framed around the entire perimeter of the glass
          • optional grip-handle position (right or left)